English: The main objective of this study was to develop an analytical method to accurately
quantify scandium in different Sc-containing matrices including inorganic
compounds, organometallic complexes and finally low grade Sc mineral ores and
residues. The organometallic complexes (Sc(acac)3, Sc(tfac)3, Sc(btfac)3, Sc(dbm)3,
Sc(hfac)3 and Sc(sacac)3) were synthesized and characterised using melting point,
IR, CHNS-micro element analysis and X-ray crystallography techniques. The study
involved the use of different mineral acids such as HNO3, HCl and H2SO4 for the
dissolution of the different samples using both open-beaker and microwave-assisted
dissolution techniques. Flux fusion using NH4F·HF flux was used for the dissolution
of columbite mineral and Ta/Nb residue samples. ICP-OES was used for
quantification of Sc in all samples as well as some of the other metals in the mineral
samples. The wavelengths were carefully selected to minimise any spectral
interferences and the matrix matching was also ensured throughout the study for
accurate measurements.
ScCl3·H2O was dissolved in water and recoveries ranging from 99.64 - 99.79 % were
obtained. Open-beaker dissolution of Sc2O3 with HNO3, HCl or H2SO4 yielded Sc
recoveries ranging from 44(7) - 99.2(4) % and these recoveries were improved with
the microwave dissolution method to recoveries between 99.8(3) and 101(1) %.
Excellent Sc recoveries from the most of the organometallic complexes (Sc(acac)3,
Sc(tfac)3, Sc(btfac)3, Sc(dbm)3 and Sc(sacac)3) ranging from 95(3) - 99.4(6) % were
obtained while Sc(hfac)3 yielded a lower than expected recovery of 80.4(4) % due to
the possibility that the molar mass from the empirical formula known is incorrect or
that an impure product was isolated.
Excellent results were obtained for the columbite ore and the Ta/Nb residue samples
(Sample A and B respectively) after the NH4F·HF fusion dissolution. In the process
of the beneficiation of Sc, magnetic separation was attempted for the removal of Fe
and Ti from the rest of the sample (both Sample A and Sample B) but was considered unsatisfactory since a large portion of the Fe in the sample did not exhibit
ferromagnetic properties and hence remained with the original portion (nonmagnetic)
of the samples. Results also indicated the loss of a relatively significant
portion of Sc in both samples. Solvent extraction with MIBK was also attempted for
the possible extraction of Ta and Nb and the results indicated that this process was
only successful to eliminate the Ta in large quantities and that both the Ta and Nb
can be extracted with MIBK at high [H2SO4] with relatively insignificant losses of Sc,
especially from Sample B.
The experimental results for the scandium analysis were validated for a large
number of validation parameters, which included accuracy, precision, sensitivity,
specificity, linearity, etc. to confirm whether the newly developed analytical
procedures were suitable for the scandium determination in terms of internationally
required standards (ISO 17025). The limit of detection (LOD) and limit of quantitation
(LOQ) for Sc were determined to be 0.000991and 0.00991 ppm respectively, which
is sufficient to measure trace amounts of scandium. The linearity of the calibration
curves was determined from the regression coefficient (R2) and ranged from 0.996 to
1.00. Statistical tests of the experimental results were calculated using the
hypothesis test of the t-statistical at 95 % confidence interval (C.I) to determine
whether the results were acceptable as recommended by ISO 17025.
Afrikaans: Die primêre doel van hierdie studie was om 'n analitiese metode te ontwikkel om skandium akkuraat in verskillende Sc-bevattende matrikse, insluitend anorganiese verbindings, organometaalkomplekse en uiteindelik lae graad Sc minerale erts en prosesafval-materiaal te kwantifiseer. ʼn Aantal organometaalkomplekse, naamlik Sc(acac)3, Sc(tfac)3, Sc(btfac)3, Sc(dbm)3, Sc(hfac)3 en Sc(sacac)3 is tydens die studie berei en met behulp van smeltpunt, IR, CHNS mikro-element analise en Xstraalkristallografie tegnieke gekarakteriseer. Verder is die vertering van die verskillende monsters met behulp van beide gewone oop beker en mikrogolfvertering in die teenwoodigheid van ‘n aantal HNO3, HCl en H2SO4 ondersoek. Die vertering en oplos van die kolumbiet minerale monster en die Ta/Nb prosesafval monsters is ook met gesmelte sout of vloeimiddelsmelting ondersoek en NH4F∙HF is hoofsaaklik as smeltmiddel gebruik. In alle gevalle is IGP-OES is vir die akkurate bepaling van die hoeveelheid Sc en ander elemente in al die anorganiese verbindings, organometaalkomplekse asook in die minerale monsters gebruik. Die golflengtes vir hierdie bepalings is sorgvuldig gekies om enige spektrale steurings te verhoed en in alle gevalle is matriksparing toegepas om die moontlike invloed van al die bygevoegde chemikalië in die Sc-bepaling uit te skakel. Die ScCl3·H2O los maklik op in water en Sc-opbrengste wat tussen 99.64 - 99.79 % wissel, is verkry. Die natvertering van Sc2O3 in HNO3, HCl of H2SO4 het Sc-opbrengste wat wissel tussen 44(7) - 99.2(4) % gelewer. Die gebruik van mikrogolfvertering in die teenwoordigheid van dieselfde sure het die Sc-opbrengste tot 99.8(3) en 101(1) % verbeter. Uitstekende Sc-opbrengste is vir die meerderheid organometaalkomplekse ((Sc(acac)3, Sc(tfac)3, Sc(btfac)3, Sc(dbm)3 en Sc(sacac)3) verkry met Sc-waardes wat tussen 95(3) en 99.4(6) % gewissel het, terwyl heelwat laer Sc-opbrenste (80.4(4) %) vir Sc(hfac)3 verkry is. Moontlike redes vir hierdie laer opbrengste kan moontlik aan die gebruik van ʼn verkeerdelike molêre massa of empiriese formule of dat ʼn onsuiwere produk geïsoleer is, toegeskryf word. Die magnetiese skeiding van Fe en Ti in beide die kolumbiet erts en die Ta/Nb prosesafval-materiaal was onbevredigend met ʼn groot hoeveelheid van die yster wat in die nie-magnetiese gedeelte agtergebly het asook betekenisvolle Sc-hoeveelhede wat in die magnetiese gedeelte verlore geraak het. Uitstekende Sc-resultate is na die NH4F∙HF vloeimiddelsmeltinig vertering vir die beide die kolumbiet erts en die Ta/Nb prosesafval-materiaal verkry. Resultate het ook die verlies van 'n relatief beduidende gedeelte van Sc in beide monsters aangedui. Die skeiding van Ta en Nb in beide die kolumbiet erts en die Ta/Nb prosesafval-materiaal met behulp van MIBK oplosmiddel-ekstraksie ondersoek. Die resultate het aangedui dat hierdie proses suksesvol is om al die Ta in beide monsters te verwyder, met relatief onbeduidende verliese van Sc. Die eksperimentele resultate vir die Sc- analise is vir 'n groot aantal valideringsparameters volgens ISO 17025 kriteria, wat onder andere akkuraatheid, presisie, sensitiwiteit, spesifisiteit, lineariteit ens. insluit, geëvalueer. Die beperking/grens van die opsporing (LOD) en laagste vlak van kwantifisering (LOQ) vir Sc was 0.000991 en 0.00991 dpm onderskeidelik bepaal. Die lineariteit van al die kalibrasie kurwes (regressie-koëffisiënt, R2) het tussen 0.996 - 1.00. gevarieer. Verdere statistiese toetse vir al die eksperimentele resultate is met behulp van ʼn hipotese toets (t-toets met ʼn op 95 % betroubaarheidsinterval) geëvalueer.
Afrikaans: Die primêre doel van hierdie studie was om 'n analitiese metode te ontwikkel om skandium akkuraat in verskillende Sc-bevattende matrikse, insluitend anorganiese verbindings, organometaalkomplekse en uiteindelik lae graad Sc minerale erts en prosesafval-materiaal te kwantifiseer. ʼn Aantal organometaalkomplekse, naamlik Sc(acac)3, Sc(tfac)3, Sc(btfac)3, Sc(dbm)3, Sc(hfac)3 en Sc(sacac)3 is tydens die studie berei en met behulp van smeltpunt, IR, CHNS mikro-element analise en Xstraalkristallografie tegnieke gekarakteriseer. Verder is die vertering van die verskillende monsters met behulp van beide gewone oop beker en mikrogolfvertering in die teenwoodigheid van ‘n aantal HNO3, HCl en H2SO4 ondersoek. Die vertering en oplos van die kolumbiet minerale monster en die Ta/Nb prosesafval monsters is ook met gesmelte sout of vloeimiddelsmelting ondersoek en NH4F∙HF is hoofsaaklik as smeltmiddel gebruik. In alle gevalle is IGP-OES is vir die akkurate bepaling van die hoeveelheid Sc en ander elemente in al die anorganiese verbindings, organometaalkomplekse asook in die minerale monsters gebruik. Die golflengtes vir hierdie bepalings is sorgvuldig gekies om enige spektrale steurings te verhoed en in alle gevalle is matriksparing toegepas om die moontlike invloed van al die bygevoegde chemikalië in die Sc-bepaling uit te skakel. Die ScCl3·H2O los maklik op in water en Sc-opbrengste wat tussen 99.64 - 99.79 % wissel, is verkry. Die natvertering van Sc2O3 in HNO3, HCl of H2SO4 het Sc-opbrengste wat wissel tussen 44(7) - 99.2(4) % gelewer. Die gebruik van mikrogolfvertering in die teenwoordigheid van dieselfde sure het die Sc-opbrengste tot 99.8(3) en 101(1) % verbeter. Uitstekende Sc-opbrengste is vir die meerderheid organometaalkomplekse ((Sc(acac)3, Sc(tfac)3, Sc(btfac)3, Sc(dbm)3 en Sc(sacac)3) verkry met Sc-waardes wat tussen 95(3) en 99.4(6) % gewissel het, terwyl heelwat laer Sc-opbrenste (80.4(4) %) vir Sc(hfac)3 verkry is. Moontlike redes vir hierdie laer opbrengste kan moontlik aan die gebruik van ʼn verkeerdelike molêre massa of empiriese formule of dat ʼn onsuiwere produk geïsoleer is, toegeskryf word. Die magnetiese skeiding van Fe en Ti in beide die kolumbiet erts en die Ta/Nb prosesafval-materiaal was onbevredigend met ʼn groot hoeveelheid van die yster wat in die nie-magnetiese gedeelte agtergebly het asook betekenisvolle Sc-hoeveelhede wat in die magnetiese gedeelte verlore geraak het. Uitstekende Sc-resultate is na die NH4F∙HF vloeimiddelsmeltinig vertering vir die beide die kolumbiet erts en die Ta/Nb prosesafval-materiaal verkry. Resultate het ook die verlies van 'n relatief beduidende gedeelte van Sc in beide monsters aangedui. Die skeiding van Ta en Nb in beide die kolumbiet erts en die Ta/Nb prosesafval-materiaal met behulp van MIBK oplosmiddel-ekstraksie ondersoek. Die resultate het aangedui dat hierdie proses suksesvol is om al die Ta in beide monsters te verwyder, met relatief onbeduidende verliese van Sc. Die eksperimentele resultate vir die Sc- analise is vir 'n groot aantal valideringsparameters volgens ISO 17025 kriteria, wat onder andere akkuraatheid, presisie, sensitiwiteit, spesifisiteit, lineariteit ens. insluit, geëvalueer. Die beperking/grens van die opsporing (LOD) en laagste vlak van kwantifisering (LOQ) vir Sc was 0.000991 en 0.00991 dpm onderskeidelik bepaal. Die lineariteit van al die kalibrasie kurwes (regressie-koëffisiënt, R2) het tussen 0.996 - 1.00. gevarieer. Verdere statistiese toetse vir al die eksperimentele resultate is met behulp van ʼn hipotese toets (t-toets met ʼn op 95 % betroubaarheidsinterval) geëvalueer.