Evaluating the accuracy of planar gated blood pool processing software using simulated patient studies

dc.contributor.authorPieters, H.
dc.contributor.authorvan Staden, J. A.
dc.contributor.authordu Raan, H.
dc.contributor.authorNel, M. G.
dc.contributor.authorEngelbrecht, G. H. J.
dc.date.accessioned2024-09-17T10:08:02Z
dc.date.available2024-09-17T10:08:02Z
dc.date.issued2024
dc.description.abstractPlanar gated blood pool (GBP-P) radionuclide imaging is a valuable non-invasive technique for assessing left ventricular ejection fraction (LVEF). Serial cardiac imaging can be performed to monitor the potential decline in LVEF among patients undergoing cardiotoxic chemotherapy. Consequently, accurate LVEF determination becomes paramount. While commercial software programs have enhanced the LVEF values' reproducibility, concerns remain regarding their accuracy. This study aimed to generate a database of GBP-P studies with known LVEF values using Monte Carlo simulations and to assess LVEF values' accuracy using four commercial software programs. We utilised anthropomorphic 4D-XCAT models to generate 64 clinically realistic GBP-P studies with Monte Carlo simulations. Four commercial software programs (Alfanuclear, Siemens, General Electric Xeleris, and Mediso Tera-Tomo) were used to process these simulated studies. The accuracy and reproducibility of the LVEF values determined with these software programs and the intra- and inter-observer reproducibility of the LVEF values were assessed. Our study revealed a strong correlation between LVEF values calculated by the software programs and the true LVEF values derived from the 4D-XCAT models. However, all the software programs slightly underestimated LVEF at lower LVEF values. Intra- and inter-observer reliability for LVEF measurements was excellent. Accurate LVEF assessment is crucial for determining the patient's cardiac function before initiating and during chemotherapy treatment. The observed underestimation, particularly at lower LVEF values, emphasises the need for the accurate and reproducible determination of these values to avoid excluding suitable candidates for chemotherapy. The software programs' excellent intra- and inter-observer reliability highlights their potential to reduce subjectivity when using the semi-automatic processing option. This study confirms the accuracy and reliability of these commercial software programs in determining LVEF values from simulated GBP-P studies. Future research should investigate strategies to mitigate the underestimation biases and extend findings to diverse patient populations.
dc.description.versionPublisher's version
dc.identifier.citationPieters, H., van Staden, J. A., du Raan, H., Nel, M. G., & Engelbrecht, G. H. J. (2024). Evaluating the accuracy of planar gated blood pool processing software using simulated patient studies. Heliyon, 10(17), e37299. https://doi.org/10.1016/j.heliyon.2024.e37299
dc.identifier.issn2405-8440 (online)
dc.identifier.urihttps://doi.org/10.1016/j.heliyon.2024.e37299
dc.identifier.urihttp://hdl.handle.net/11660/12769
dc.language.isoen
dc.publisherElsevier
dc.rights.holderAuthor(s)
dc.rights.licensehttps://creativecommons.org/licenses/by-nc/4.0/
dc.subjectGated blood pool studies
dc.subjectLeft ventricular ejection fraction
dc.subjectMonte Carlo simulations
dc.subject4D-XCAT models
dc.titleEvaluating the accuracy of planar gated blood pool processing software using simulated patient studies
dc.typeArticle
Files
Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Pieters_Evaluating the accuracy of planar gated blood pool_2024.pdf
Size:
3.31 MB
Format:
Adobe Portable Document Format
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.63 KB
Format:
Item-specific license agreed upon to submission
Description: